What Is Derating

Derating is a protective measure which allows the use of power supplies at high temperatures, at high altitudes or in alternative mounting orientations. In this blog article you will learn what you should consider when it comes to derating.

Most power supply manufacturers specify ratings for lifetime, output current, and reliability (e.g. MTBF) for their products. However, this information only applies under certain environmental conditions. In particular, the temperature limits must be observed so that the components in the power supply do not overheat or wear out prematurely. A necessary means to regulate the temperature is the so-called derating.

What does derating mean?

Derating means the reduction of the output power depending on the ambient conditions. Derating is therefore a recommended protective measure for electronic components and devices to protect them from high temperatures and prevent failures. The power reduction is precisely specified for each power supply. The necessary procedure is described in the respective data sheet.

When is derating necessary for a power supply?

There are several environmental conditions that increase the temperature of the power supply and thus are a potential risk. These include high ambient temperatures, an installation altitude of more than 2,000 meters and mounting orientations that deviate from the recommended installation

Refer to more articles:  What Is Retail Fraud 3rd Degree

Derating at high ambient temperatures

Nearly all industrial power supplies require derating above a certain ambient temperature in order to protect the electronics. Above a defined temperature limit, the output power must be reduced linearly. The corresponding value can be found in the data sheet. For example, the 960 W (24 V, 40 A) power supply QS40.241 requires a derating of 24 W/°C above 60 °C. If you want to use the device near its temperature limit of 70 °C, only a maximum of 720 W would be advisable to maintain the life expectancy or (MTBF).

This value must be taken into account when selecting a power supply – especially if a device requires derating even at lower temperatures. Many competitive power supplies demand the reduction of the output power from 40 °C, however, such temperatures are common in a closed control cabinet without a cooling system. System engineers basically have 4 options to solve this problem.

  1. Choose a power supply that has a higher temperature limit before it requires derating.
  2. Choose a power supply unit with a higher output power in order to have a sufficient power budget available despite derating.
  3. Connect multiple identical power supplies in parallel to get the total power you need.
  4. Install a cooling system.

All options mean higher investments within the planning phase of the system, but are usually worth it in terms of higher reliability and longer service life.

Even if the system is subsequently expanded, it must be checked whether the power supply can provide sufficient power reserves under the prevailing conditions.

Refer to more articles:  What Is A Fuckgirl

Derating at altitudes above 2,000 meters

Derating at alternative mounting orientations

If you need to mount the power supply in an orientation that deviates from the recommended standard installation, derating or limiting the ambient temperature is also necessary. The reason is the functionality of convection-cooled power supplies. The air flow inside the device cools the temperature-sensitive components, such as electrolytic capacitors, and the warm air is discharged to the outside. The recommended standard installation position is based on a “chimney effect”. The cool air enters the power supply at the lower ventilation grille, heats up due to the power losses of certain components and is discharged again on the top of the device.

In the development phase the devices are designed according to the cool design principles. Temperature-sensitive components that determine the lifetime are placed in the cool spots in the power supply. The developers position other components (e.g. transformers) that heat up most at the top of the power supply so that they do not heat up the other components. In addition, the PULS developers make sure that the air can always flow freely and is not blocked by components.

If the device is mounted upside down or e.g. on a table-top (see graphic 2-4), this affects the air flow. Without reducing the output power, the components could overheat, which has a negative impact on the lifetime and, in the worst case, can lead to a failure of the power supply.

Graphic 2: Derating for the standard orientation of the CP20.241 (24 V, 20 A)

Refer to more articles:  What Are Switchback Lights

Graphic 3: Derating for an upside-down orientation of the CP20.241 (24 V, 20 A)

Graphic 4: Derating for the table-top mounting of the CP20.241 (24 V, 20 A)

Conclusion

Derating is necessary for almost all industrial power supplies above a certain temperature, installation altitude or in a deviating mounting orientation. With many manufacturers, however, you have to search for the corresponding specification in the data sheet for quite some time. PULS provides the necessary information for derating on the front page of its data sheets. In this way, system developers and technicians can see this important information at first glance and adapt the power supply perfectly to the ambient conditions during installation.

Related Posts

What Does 150 Mean

Meaning of Numbers: The Number 150 The English phrase “hundred and fifty,” used for the number 150, is recorded 38 times in 34 King James Bible verses.You…

What To Wear To A Quince Men

You might be thinking that what do men wear to a quinceanera. There are many different quinceanera men’s dress code options available.You may be interested What Is…

What Is Porch Pick Up

What Is Porch Pick Up

APPLE | SPOTIFY | AUDIBLE Porch pick-up is an opportunity to offer a unique experience to your customer’s beyond the standard customer service. Before you do, it…

What Does Blue Underwear Mean On New Year's

What Does Blue Underwear Mean On New Year’s

New Year’s Eve is a time for celebration, reflection, and setting intentions for the year ahead. While many people focus on their outfits and accessories for the…

What Time Is Sentencing For Murdaugh

Alex Murdaugh’s theft of millions of dollars was about to be revealed so he killed his wife and son to buy time to figure a way out,…

What Is Hard Salami

Salami is a beloved deli meat, celebrated for its rich, savory flavors and versatility in various culinary creations. Among the myriad of salami varieties, Hard and Genoa…