What Is Pvab

This tracing shows the limitations of the programming of an overly prolonged post-ventricular atrial blanking period. Failure to sense one out of two atrial signals during a flutter episode leads to the occurrence of poorly-tolerated paced tachycardia in this pacemaker-dependent patient. Reducing its value allows the diagnosis of atrial arrhythmia and rapid mode switching. To avoid crosstalk while maintaining the ability to properly sense atrial arrhythmias, the programming can teeter on a balance between blanking periods and atrial sensitivity.

Post-ventricular atrial blanking (PVAB) is an absolute refractory period applied in the atrium after ventricular sensing and pacing. Its duration can be viewed on the tracing by a bold line following ventricular pacing. Its purpose is to avoid the sensing of the ventricular pacing artifact and the depolarization of the intrinsic or paced ventricle by the atrial channel. The atrial events occurring during this absolute refractory period are not sensed and are therefore not taken into account for the counting of atrial arrhythmias (calculation of the filtered atrial rate). The duration of the atrial blanking is programmable between 60 to 250 ms with a nominal value of 150 ms.

The post-ventricular atrial refractory period (PVARP) is a relative refractory period that follows the PVAB. Its main function is to prevent the occurrence of pacemaker-mediated tachycardia by classifying retrograde atrial conduction as refractory (AR on the marker chain). To avoid recycling ventricular pacing due to retrograde atrial conduction, the PVARP must theoretically be programmed to a value greater than the patient’s retrograde ventriculoatrial conduction time. The mean value of the retrograde conduction time is between 220 and 280 ms depending on the patients, although can sometimes be even longer with the need to extend the PVARP. A PVARP programmed too long can, however, induce the appearance of a 2:1 block during exercise at quite low intrinsic rates when the pacemaker is functioning in atrial tracking mode (DDD or VDD). The PVARP is programmable between 125 and 475 ms (nominal value 275 ms). The programming of a dynamic PVARP enables adjusting the value of the PVARP according to the heart rate thereby distancing the 2:1 point. This setting can be set to Off, Low, Medium, High. The PVARP is shortened linearly in order to reach a target atrial sensing window which is even more extensive if the parameter is set to High. It is also necessary to program the shortest PVARP (programmable between 125 and 475 ms, nominal value 175 ms).

Refer to more articles:  What Time Do Bars Close In Nashville Tennessee

Related Posts

What Is Cpi Training For Special Education

We take a look at what CPI is and why it is so beneficial for de-escalating crises for children with autism in combination with several ABA strategies.You…

What Is 1 15 As A Decimal

Converting 1/15 to a decimal is quite possibly one of the easiest calculations you can make. In this (very short) guide, we’ll show you how to turn…

What Is Coryxkenshin Net Worth

What Is Coryxkenshin Net Worth

You may be interested What’s God’s Favorite Color What Is Head Pressure Hvac What Is A Dry Van Driver What Is 3 Of 1200 What Is Flexibound…

What Time Is 22 45

Convert 2245 military time into standard (regular) AM/PM format. You may be interested What Was George Jones Net Worth Unveiling the Fragile Mystery of Silence What Next…

What Do Dental Implants Look Like

With changing technology, dental implants have become a go-to alternative to some other procedures. Dental implants work by replacing missing teeth as well as keeping prosthetics, like…

What Channel Is Cbs Uverse

Are you a fan of CBS shows and wondering if you can access them on AT&T? Well, you’re in luck! AT&T offers an exciting lineup of CBS…